High-bandwidth voltage transducer with galvanic isolation
DC voltage transducer for direct current with wide bandwidth
The IsoBand V is a powerful **DC voltage transducer** for direct current applications, designed for measurement tasks where fast changes of DC signals up to 8 MHz occur.
The transducer scales **DC voltage** from an input range of ±5 V to ±2000 V, linearly and **isolated**, down to a standard ±10 V output.
Its patented, fully differential architecture ensures accurate signal reproduction and integrates seamlessly into existing measurement chains with compatible accessories and **DC-DC topology** – serving as a reliable **DC converter** or **DC-DC converter** wherever voltage must be captured precisely at high slew rates.
High-voltage transducer – galvanically isolated and protected
As a **high-voltage transducer**, the IsoBand V guarantees robust, **galvanically isolated** signal transmission with excellent linearity.
The differential downscaling provides strong immunity against common-mode disturbances, while integrated protection safeguards the product.
In **DC-DC** environments, the converter delivers reproducible **data** and combines the benefits of a precise voltage transducer with long-term industrial durability – ideal for laboratory, development, and production settings where high-frequency content, PWM signals, and steep edges must be reliably captured.
Measuring differential voltage – fast, accurate, and reliable
For those who need to **measure differential voltage**, the IsoBand V provides a high-precision **measuring device** for advanced **voltage measurement**.
Its differential architecture minimizes errors and allows clean acquisition of both **voltage** and **current**, even in complex **circuits**.
This ensures reliable **measurement** of transients, VFD outputs, and overvoltage events while maintaining high bandwidth and traceable results.
Thus, the Verivolt IsoBand V Series is a future-proof solution for modern electrical test and measurement applications.
Specifications of the IsoBand V Series
- Three-way galvanic isolation: channel-to-channel, primary-to-secondary, signal-to-power
- Input voltage: 5 V to 2000 V
- Output voltage: 5 V, 10 V
- Isolation between primary and secondary: up to 1.5 kV (continuous) and 5 kV (max. 1 min operation)
- Bandwidth (DC): up to 8 MHz
- DIN rail mount for fast installation
- Voltage drop measurement for channel isolation in every DAQ
- Compact form factor: enables high channel density in monitoring systems
- High input impedance: ensures signal integrity across various sources
- Low output impedance: compatible with most ADCs and oscilloscopes, supports long cable runs
- Proprietary digital technology: enables signal processing at maximum bandwidth
- High common-mode rejection: prevents unwanted disturbances in output signals
- Overvoltage protection: safeguards connected devices such as oscilloscopes
- Flat frequency response: stable signal characteristics across a wide frequency range
- High linearity
- Operating temperature: -25 °C to 70 °C
- Weight: 0.238 kg (8.4 oz)
Application examples of the IsoBand V Series
Voltage monitoring for e.g.:
- Batteries
- Fuel cells
- Electric motors
- Photovoltaic (PV) systems
- and many other use cases...
| Input Voltage: | 5 V, 10 V, 15 V, 20 V, 50 V, 100 V, 150 V, 200 V, 1000 V, 1500 V, 2000 V |
|---|---|
| Interfaces: | Analog |
| Output Voltage: | 5 V, 10 V |
Related links to "High Bandwidth Voltage Transducer with Galvanic Isolation | IsoBand V"
Available documents (Subject to change)
Scope of delivery of the High Bandwidth Voltage Transducer with galvanic Isolation of the IsoBand V-Series
- Unit(s) of the IsoBand V-Series
Verivolt is an American manufacturer of current transformers, voltage transformers, power transformers and filters, with the specialty of very high galvanic isolation of 1kV and above.
Many of the products can be used directly for DIN or top hat rail mounting.
The range of values varies from small currents in the mA range up to 2kA, and isolation of 5kV between input and output with bandwidths >1MHz.