- Order number: IH-IT8900GL-Serie
ITECH IT8900G/L Series
High speed and high power DC electronic load
Power: up to 54 kW, Voltage: up to 1200 V, Current: up to 2160 A
IT8900G/L series high speed and high power DC electronic load features as fast current rise and fall and low voltage loading capability. It has three voltage ranges: 150V, 600V, 1200V, and the maximum power ranges from 2 kW to 54 kW for a single unit. Tt has wide-range design, independent master unit control. It supports master-slave parallel connection and the maximum power can be extended to 600kW. It has high power density, only 4U height unit can input 6kW. IT8900G/L has up to 8/4 operating modes with dynamic mode, OCP, OPP test, auto test and battery test. It has built-in CAN, LAN, GPIB, USB, RS232 and analog interfaces, etc., and has full protection. The IT8900G/L can be applied to the testing of EV batteries, A/D power supplies, server power supplies, DC charging piles, on-board chargers (OBCs), industrial motors, fuel cells, power electronics, and other power electronics products.
Application of the DC electronic load of the IT8900G/L Series
- Testing of server power supplies, high-voltage UPS, and communication power supplies
- Testing of virtual loads for natural energy sources (solar arrays, wind power generation)
- Testing of DC-DC modules, AC-DC modules and other power electronic components
- Discharge testing of fuel cells, power batteries, and lead storage batteries
- Aging test of fuses and relays
- Smart manufacturing, safety testing of industrial motors (e.g., unmanned trucks, robots, etc.)
- Testing of DC charging piles, on board chargers, power electronics, etc.
Specifications of the DC electronic load of the IT8900G/L Series
- Maximum power of single unit: 2-54 kW
- Voltage range: 150 V, 600 V, 1200 V
- Current range: 4U module up to 600A, master/slave parallel control, power expansion up to 600 kW
- Multiple operating modes: CC, CV, CR, CP, CC+CV, CV+CR, CR+CC, CP+CC (IT8900L only supports CC, CV, CR, CP)
- Fast current rise and fall and 30 kHz dynamic mode (30 kHz only for 150 V G-Series models)
- CV loop speed adjustable to match different power supplies
- Low voltage and high current loading, internal resistance about 0.7mΩ
- 500 kHz high speed voltage and current sampling rate
- Time measurement, battery discharge test
- Short circuit simulation, automatic test function
- Soft power on, soft power off to prevent voltage fluctuation during on/off
- Timing control list programming, OCP/OPP test
- I-monitor
- Built-in LAN, USB, RS232, GPIB, CAN, external analog
- Highly accurate voltage and current measurement
- Support OVP, OCP,OPP, OTP, current oscillation protection, current limit, power limit, fan blocking protection, reverse alarm, etc.
- Power failure memory function, memory capacity of 100 groups
- Independent control by master unit , easy to maintain and install
Models of the DC electronic load of the IT8900G/L Series
Model | Voltage | Current | Power | Resolution | Accuracy | Size |
IT8902G-150-200 | 150 V | 200 A | 2 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 4 U |
IT8902L-150-200 | 150 V | 200 A | 2 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 4 U |
IT8904G-150-400 | 150 V | 400 A | 4 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 4 U |
IT8904L-150-400 | 150 V | 400 A | 4 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 4 U |
IT8906G-150-600 | 150 V | 600 A | 6 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 4 U |
IT8906L-150-600 | 150 V | 600 A | 6 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 4 U |
IT8908G-150-800 | 150 V | 800 A | 8 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 8 U |
IT8908L-150-800 | 150 V | 800 A | 8 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 8 U |
IT8912G-150-1200 | 150 V | 1200 A | 12 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 8 U |
IT8912L-150-1200 | 150 V | 1200 A | 12 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 8 U |
IT8918G-150-1800 | 150 V | 1800 A | 18 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 15 U |
IT8918L-150-1800 | 150 V | 1800 A | 18 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 15 U |
IT8924G-150-2400 | 150 V | 2400 A | 24 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 27 U |
IT8924L-150-2400 | 150 V | 2400 A | 24 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 27 U |
IT8930G-150-2400 | 150 V | 2400 A | 30 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 27 U |
IT8930L-150-2400 | 150 V | 2400 A | 30 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.15%FS) | 27 U |
IT8936G-150-2400 | 150 V | 2400 A | 36 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 27 U |
IT8936L-150-2400 | 150 V | 2400 A | 36 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.15%+0.15%FS) | 27 U |
IT8942G-150-2400 | 150 V | 2400 A | 42 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.15%FS) | 37 U |
IT8942L-150-2400 | 150 V | 2400 A | 42 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.15%+0.2%FS) | 37 U |
IT8948G-150-2400 | 150 V | 2400 A | 48 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.2%FS) | 37 U |
IT8948L-150-2400 | 150 V | 2400 A | 48 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.2%+0.2%FS) | 37 U |
IT8954G-150-2400 | 150 V | 2400 A | 54 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.15%+0.2%FS) | 37 U |
IT8954L-150-2400 | 150 V | 2400 A | 54 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.2%+0.25%FS) | 37 U |
IT8902G-600-140 | 600 V | 140 A | 2 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 4 U |
IT8902L-600-140 | 600 V | 140 A | 2 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 4 U |
IT8904G-600-280 | 600 V | 280 A | 4 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 4 U |
IT8904L-600-280 | 600 V | 280 A | 4 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 4 U |
IT8906G-600-420 | 600 V | 420 A | 6 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 4 U |
IT8906L-600-420 | 600 V | 420 A | 6 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 4 U |
IT8908G-600-560 | 600 V | 560 A | 8 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 8 U |
IT8908L-600-560 | 600 V | 560 A | 8 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 8 U |
IT8912G-600-840 | 600 V | 840 A | 12 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 8 U |
IT8912L-600-840 | 600 V | 840 A | 12 kW | 1mV/1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 8 U |
IT8918G-600-1260 | 600 V | 1260 A | 18 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 15 U |
IT8918L-600-1260 | 600 V | 1260 A | 18 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 15 U |
IT8924G-600-1680 | 600 V | 1680 A | 24 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 27 U |
IT8924L-600-1680 | 600 V | 1680 A | 24 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 27 U |
IT8930G-600-2100 | 600 V | 2100 A | 30 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 27 U |
IT8930L-600-2100 | 600 V | 2100 A | 30 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 27 U |
IT8936G-600-2400 | 600 V | 2400 A | 36 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.15%FS) | 27 U |
IT8936L-600-2400 | 600 V | 2400 A | 36 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.15%FS) | 27 U |
IT8942G-600-2400 | 600 V | 2400 A | 42 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.15%FS) | 37 U |
IT8942L-600-2400 | 600 V | 2400 A | 42 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.15%FS) | 37 U |
IT8948G-600-2400 | 600 V | 2400 A | 48 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.15%FS) | 37 U |
IT8948L-600-2400 | 600 V | 2400 A | 48 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.15%FS) | 37 U |
IT8954G-600-2400 | 600 V | 2400 A | 54 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.15%FS) | 37 U |
IT8954L-600-2400 | 600 V | 2400 A | 54 kW | 1mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.15%FS) | 37 U |
IT8902G-1200-80 | 1200 V | 160 A | 2 kW | 10mV/0.1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 4 U |
IT8902L-1200-80 | 1200 V | 160 A | 2 kW | 10mV/0.1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 4 U |
IT8904G-1200-160 | 1200 V | 240 A | 4 kW | 10mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 4 U |
IT8904L-1200-160 | 1200 V | 240 A | 4 kW | 10mV/1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 4 U |
IT8906G-1200-240 | 1200 V | 320 A | 6 kW | 10mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 4 U |
IT8906L-1200-240 | 1200 V | 320 A | 6 kW | 10mV/1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 4 U |
IT8908G-1200-320 | 1200 V | 80 A | 8 kW | 10mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 8 U |
IT8908L-1200-320 | 1200 V | 80 A | 8 kW | 10mV/1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 8 U |
IT8912G-1200-480 | 1200 V | 480 A | 12 kW | 10mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 8 U |
IT8912L-1200-480 | 1200 V | 480 A | 12 kW | 10mV/1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 8 U |
IT8918G-1200-720 | 1200 V | 720 A | 18 kW | 10mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 15 U |
IT8918L-1200-720 | 1200 V | 720 A | 18 kW | 10mV/1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 15 U |
IT8924G-1200-960 | 1200 V | 960 A | 24 kW | 10mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 27 U |
IT8924L-1200-960 | 1200 V | 960 A | 24 kW | 10mV/1mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 27 U |
IT8930G-1200-1200 | 1200 V | 1200 A | 30 kW | 10mV/1mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 27 U |
IT8930L-1200-1200 | 1200 V | 1200 A | 30 kW | 10mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 27 U |
IT8936G-1200-1440 | 1200 V | 1440 A | 36 kW | 10mV/10mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 27 U |
IT8936L-1200-1440 | 1200 V | 1440 A | 36 kW | 10mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 27 U |
IT8942G-1200-1680 | 1200 V | 1680 A | 42 kW | 10mV/10mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 37 U |
IT8942L-1200-1680 | 1200 V | 1680 A | 42 kW | 10mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 37 U |
IT8948G-1200-1920 | 1200 V | 1920 A | 48 kW | 10mV/10mA | ±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS) | 37 U |
IT8948L-1200-1920 | 1200 V | 1920 A | 48 kW | 10mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 37 U |
IT8954G-1200-2160 | 1200 V | 2160 A | 54 kW | 10mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.15%FS) | 37 U |
IT8954L-1200-2160 | 1200 V | 2160 A | 54 kW | 10mV/10mA | ±(0.05%+0.05%FS)/ ±(0.1%+0.1%FS) | 37 U |
GW-PEL-5000C-Serie
GW-PEL-3000E-Serie
BS-MF-1051
MPE-MLx-Serie
KW-E5000-Serie
GW-GPD-Serie
GW-APS-7000E-Serie
GW-APS-7000-Serie
GW-AEL-5000-Serie
GW-ASR-2000-Serie
GW-PEL-500-Serie
GW-PEL-3000-3000H-Serie
MPE-XR-Serie