For professionals (EU countries) | All data subject to change
Give us a call: +49(0)7032 / 895 93-3

Multichannel potentiostat LR / HR

Price on request

Prices plus VAT plus shipping costs

Channels:

Current:

max. freq. for EIS:

  • PS-C-MES4
Available downloads (Subject to change)
PalmSens MultiEmStat4 LR / HR Potentiostat / galvanostat / optional impedance analyzer Potential... more
Product information "Multichannel potentiostat LR / HR"

PalmSens MultiEmStat4 LR / HR
Potentiostat / galvanostat / optional impedance analyzer
Potential range: up to ±5 V (LR) , ±8 V (HR), current: up to ±30 mA (LR), up to ±200 mA (HR), EIS frequency: up to 200 kHz

The MultiEmStat4S is a compact potentiostat, galvanostat and, optionally, frequency response analyzer (FRA) for electrochemical impedance spectroscopy (EIS) with 4, 8 or 12 channels. The MultiEmStat4 is available in two versions: The Low Range version is ideal for applications that require a low current measurement range up to 1 nA, whereas the High Range version is very suitable for applications that use a maximum current of 200 mA.

Possible applications of the multichannel potentiostat PalmSens MultiEmStat4 LR / HR:

Research and development in the field of:

  • Analytical chemistry
  • Sensor development
  • Corrosion
  • Electrochemistry
  • etc.

Available models of the multichannel potentiostat PalmSens MultiEmStat4 LR / HR

Model Potential range Current Channels FRA/EIS frequency
PS-C-MES4-04CH-LR.F0 ±5 V ±30 mA 4 -
PS-C-MES4-04CH-LR.F1 ±5 V ±30 mA 4 bis 200 kHz
PS-C-MES4-08CH-LR.F0 ±5 V ±30 mA 8 -
PS-C-MES4-08CH-LR.F1 ±5 V ±30 mA 8 bis 200 kHz
PS-C-MES4-12CH-LR.F0 ±5 V ±30 mA 12 -
PS-C-MES4-12CH-LR.F1 ±5 V ±30 mA 12 bis 200 kHz
PS-C-MES4-04CH-HR.F0 ±8 V ±200 mA 4 -
PS-C-MES4-04CH-HR.F1 ±8 V ±200 mA 4 bis 200 kHz
PS-C-MES4-08CH-HR.F0 ±8 V ±200 mA 8 -
PS-C-MES4-08CH-HR.F1 ±8 V ±200 mA 8 bis 200 kHz
PS-C-MES4-12CH-HR.F0 ±8 V ±200 mA 12 -
PS-C-MES4-12CH-HR.F1 ±8 V ±200 mA 12 bis 200 kHz
Specifications of the multichannel potentiostat PalmSens MultiEmStat4 LR / HR: Potential... mehr

Specifications of the multichannel potentiostat PalmSens MultiEmStat4 LR / HR:

  • Potential range: up to ±5 V (LR) / ±8 V (HR)
  • FRA/EIS frequency: up to 200 kHz
  • Channels: 4, 8 or 12
  • Current: up to ±30 mA (LR) / up to ±200 mA (HR)
  • Current measuring ranges: 8 (1 nA to 10 mA)
  • AC amplitude: 1 mV to 0.9 V (RMS)
  • Power supply: external, 12 V
  • Communication: USB
  • 500 MB internal memory per channel
Options & accessories of the multichannel potentiostat PalmSens MultiEmStat4 LR / HR:... mehr

Options & accessories of the multichannel potentiostat PalmSens MultiEmStat4 LR / HR:

 

Model

Specifications

Description

Function modules

GI.CH-MES4

Individual galvanic isolation

Adding galvanic isolation per channel to perform floating measurements

Scope of delivery of the multichannel potentiostat PalmSens MultiEmStat4 LR / HR: 1 x... mehr

Scope of delivery of the multichannel potentiostat PalmSens MultiEmStat4 LR / HR:

  • 1 x MultiEmStat4
  • 1 x 12 V power supply
  • 1 x USB cable
  • 1 x cell cable for each channel
  • 1 x set of alligator clips for each channel
  • 1 x PalmSens dummy cell
  • 1 x MultiTrace software (on USB stick)
  • 1 x user manual
  • 1 x Quick Start Guide
  • 1 x Calibration report for each channel

PalmSens provides a comprehensive range of instruments for most types of electrochemistry with an emphasis on mobility. The flagship instrument, the PalmSens4, is one of the most versatile and compact frequency response analysis (FRA) / EIS capable device in the market. Among the probably smallest potentiostat modules in the world is the EmStat with its dimensions of 43 x 25 x 11 mm.
Typical devices: Potentiostat, Galvanostat