Skip to main content Skip to search Skip to main navigation
For professionals (EU) | All data subject to change

Voltage Sensor Module with Galvanic Isolation | IsoBlock V-4c Series

Product Information "Voltage Sensor Module with Galvanic Isolation | IsoBlock V-4c Series"

Verivolt IsoBlock V-4c Series – Galvanically Isolated Voltage Sensor Module

Voltage Sensor with Intelligent Signal Processing

The IsoBlock V-4c Series was developed as an advanced voltage sensor for precise measurements, even in complex high-voltage applications. Each galvanically isolated module is fully compatible with common data acquisition systems and can be flexibly integrated into test benches.

As a robust voltage sensor, the series reliably analyzes power quality and delivers reproducible results. Thanks to optimized power efficiency and high durability, each device handles demanding signals, making it ideal for measuring voltage quality.

Galvanic Isolation for Safe Electrical Circuits

Consistent galvanic isolation ensures effective separation between input and output signals. Each channel is electrically isolated, protecting independent signal paths against unwanted feedback. This architecture helps protect sensitive circuits against interference, even at high voltages – a key advantage for safe and reliable testing.

Voltage Measurement Device for Research and Industry

As an advanced voltage measurement device, the series combines precise voltage measurements with a high level of safety. It complements conventional measuring instruments such as multimeters, digital voltmeters, voltage testers, and voltage meters, delivering stable results even when measuring parallel circuits. The IsoBlock V-4c Series combines advanced isolation technology with flexible integration into professional test environments.

Galvanically Isolated! Precise! Easy to Integrate!

Contact our experts today to discuss your project and receive professional technical consulting!

Interfaces: Analog-I/O
Output Voltage: 5 V, 7 VAC, 10 V, Custom

Related links to "Voltage Sensor Module with Galvanic Isolation | IsoBlock V-4c Series"

Specifications of the IsoBlock V-4c Series

  • Galvanic 3-way isolation: channel-to-channel, primary-to-secondary, signal-to-power
  • Input voltage*1: 10 mV to 1500 V, 150 VAC to 500 VAC
  • Output voltage*2: 7 VAC, 10 V
  • Isolation between primary and secondary side: up to 5 kV (max. 1 minute operation), 10 kV (max. 1 µs)
  • Accuracy*3: standard 0.2%, high 0.1%, standard 0.2% + NIST certificate, high 0.1% + NIST certificate
  • Output resistance: 20 Ω
  • Bandwidth (DC): 100 kHz (standard), up to 300 kHz (custom)
  • Output offset voltage: < ±500 µV (standard), < ±1 mV (limit)
  • Measurement of voltage drop for channel isolation for any DAQ
  • Simple installation
  • DIN rail mounting for fast installation
  • Operating temperature: −25 °C to 70 °C
  • Weight: 0.8 kg (28.2 oz)

*1 Optional: custom input voltage
*2 Optional: custom output voltage
*3 Optional: custom accuracy

Options & Accessories of the Voltage Sensor Module with Galvanic Isolation of the IsoBlock V-4c Series

  • NIST calibration of accuracy
  • Customized input voltage
  • Customized output voltage
  • Customized bandwidth

Scope of Delivery of the Voltage Sensor Module with Galvanic Isolation of the IsoBlock V-4c Series

  • Unit(s) of the IsoBlock V-4c Series

Applications of the IsoBlock V-4c Series

Voltage monitoring for systems such as:

  • Batteries
  • Fuel cells
  • Electric motors
  • Photovoltaics (PV)
  • and more

Verivolt Sensors and Measurement Solutions for Electrical Quantities

Measure Voltage and Current Across Different Potentials

Verivolt develops voltage and current sensors as well as galvanically isolated transducers for measurement tasks in power electronics, test systems, and high-voltage applications. The portfolio includes single- and multi-channel measurement modules from the IsoBlock and IsoBand families for voltage, current, and differential voltage measurements.

IsoBlock and IsoBand for Different Measurement Tasks

Depending on the product family, measurement range, galvanic isolation, bandwidth, and output signal vary. Many IsoBlock and IsoBand modules are designed for DIN-rail mounting. Depending on the sensor, measurement ranges extend from low currents to high-current applications and from low differential voltages into the kilovolt range.

Integrate Measurement Signals into DAQ Systems and Test Setups

For connection to data acquisition systems (DAQ), digitizers, and other measurement equipment, many Verivolt transducers provide scaled analog output signals. Galvanically isolated channels support measurements at different ground and common-mode potentials and simplify the design of multi-channel measurement systems.

Applications in Power Electronics, Battery Systems, and High Voltage

Typical applications include battery and energy storage systems, fuel cells, EV charging systems, variable frequency drives, motors, photovoltaics, and power electronics. For specialized applications, Verivolt also offers the IsoBlock Q-4c, a galvanically isolated signal amplifier for quench detection in superconducting magnets.

Filter products
Skip product gallery

Similar Items

Verivolt IsoBlock I-ZF-Series | view: front right
Zero Flux High Performance Current Sensor | IsoBlock I-ZF Series

VV-IsoBlock-I-ZF-Serie


Output voltage: 5 V / 10 V / 7 VAC, Input current: 20 A - 2000 A / 100 AAc - 2000 AAC

Price on request

Prices plus VAT
Verivolt IsoBlock V-1c - View front right
Verivolt IsoBlock V-1c | Differential Voltage Sensor

VV-ISOBLOCK-V-1C-Serie


Measurement Range: ±5 to ±1500 V, Bandwidth: DC to 100 kHz, Isolation: ±1500 V Continuous / 5000 V for 1 min

Regular price: From €320.00
Prices plus VAT
Verivolt IsoBlock V-3P series | View: front right
Verivolt IsoBlock V-3P | Three-Phase Voltage Sensor

VV-ISOBLOCK-V-3P-Serie


Input Voltage: 150–1000 VAC, Bandwidth: up to 100 kHz, Accuracy: up to 0.1%

Price on request

Prices plus VAT
Verivolt IsoBand V  | view: front
Verivolt IsoBand V | Galvanically Isolated Voltage Transducer

VV-IsoBand-V-Serie


Input Range: ±5 to ±2000 V, Bandwidth: DC to 8 MHz, Isolation: 1500 V continuous / 5000 V peak

Regular price: €1,177.00
Prices plus VAT