Skip to main content Skip to search Skip to main navigation
For professionals (EU) | All data subject to change

Galvanically Isolated Differential Voltage Sensor

Verivolt IsoBlock V-3P: Four-Channel Three-Phase Voltage Measurement up to 1000 VAC

The Verivolt IsoBlock V-3P Series is designed for galvanically isolated voltage measurements in three-phase systems. Depending on the version, the four-channel differential voltage sensor covers input measurement ranges from 150 VAC to 1000 VAC. The bandwidth is up to 100 kHz, with accuracy of up to 0.1% depending on the version.

Measure Phase-to-Phase and Phase-to-Neutral Voltages

The IsoBlock V-3P measures voltages in three-phase systems including the neutral conductor. In a delta configuration, phase-to-phase voltages can be output; in a star or wye configuration, phase-to-neutral voltages can be output. This makes the three-phase voltage sensor suitable for multi-channel voltage measurement in electrical three-phase systems.

Galvanic Isolation for Differential Voltage Measurements

Each channel provides galvanic isolation between input and output as well as its own isolated reference. This helps decouple high common-mode voltages from the downstream measurement system. Common-mode rejection is 112 dB at 60 Hz. An input protection stage also protects the sensor against transient overvoltages.

Scaled Output Signal for DAQ Systems

The IsoBlock V-3P operates as a differential divider network and generates a 7 VAC scaled version of the input signal. An anti-aliasing filter is integrated into the signal conditioning stage. The differential output signal can then be processed by suitable data acquisition systems and DAQs.

Alternative Products

If you only require one galvanically isolated measurement channel and more flexible measurement ranges up to 1.5 kV, we recommend the Verivolt IsoBlock V-1c Series. Do you need significantly higher bandwidth for fast transients or PWM signals? Then the Verivolt IsoBand V Series with up to 8 MHz bandwidth and measurement ranges up to 2000 V is a suitable alternative.

Related Product Categories

Signal Amplifiers | Transducers

Which IsoBlock V-3P model is right for your measurement application?

The measurement range, accuracy, and integration into the data acquisition system determine the appropriate configuration. We’ll help you select the right IsoBlock V-3P for your three-phase and differential voltage measurements.

Variants

Filter products

Specifications

Input Measurement Ranges ±150 VAC, ±250 VAC, ±500 VAC, ±700 VAC or ±1000 VAC
Channels 4
Galvanic Isolation 3-way isolation
Accuracy ±(0.2% of reading + 0.005% of range) or ±(0.1% of reading + 0.005% of range)
Bandwidth (-3 dB) DC to 100 kHz
Common-Mode Rejection at 60 Hz 112 dB
Primary-to-Secondary Isolation Voltage > ±1500 V
Maximum Common-Mode Transient Voltage 5000 V for 1 minute
Maximum Differential-Mode Transient Voltage 2000 V at 65 °C
Output Voltage 7 VAC
Output Differential signal pair
Differential Divider Network With anti-aliasing filter at the output and a scaled 7 VAC output signal
Isolated Reference Separate isolated reference for each input channel
Differential Input Impedance 8 MΩ
Input-to-Output Non-Linearity < 0.04%
Maximum Phase Shift at 60 Hz < 0.05°
Maximum Through Delay 3.8 µs
Insulation Impedance > 10 GΩ || 2 pF
Output Impedance 20 Ω
Supply Voltage 12 to 28 V
Connection Type Spring-cage terminals
Mounting DIN rail
Operating Temperature -25 to 70 °C
Storage Temperature -40 to 80 °C
Weight 198 g
Plug-and-Play Easy reconfiguration for different measurement tasks

Options & Accessories

NIST calibration for accuracy

Scope of Delivery

IsoBlock V-3P Series unit(s)

Applications

Three-Phase Power Monitoring Voltage measurement in three-phase systems
Grid-Tied Inverter Testing Galvanically isolated measurement of three-phase input and output voltages
Motor Drive Measurements Voltage measurement at the inputs and outputs of frequency converters and motor drives
Power Quality Analysis Measurement of three-phase voltages for power quality testing
Delta and Wye Systems Phase-to-phase measurements in delta configurations and phase-to-neutral measurements in wye configurations
DAQ-Based Measurement Systems and Test Benches Transfer of differential output signals to computer-based data acquisition systems

Links & Downloads

Supplier

Verivolt Sensors and Measurement Solutions for Electrical Quantities

Measure Voltage and Current Across Different Potentials

Verivolt develops voltage and current sensors as well as galvanically isolated transducers for measurement tasks in power electronics, test systems, and high-voltage applications. The portfolio includes single- and multi-channel measurement modules from the IsoBlock and IsoBand families for voltage, current, and differential voltage measurements.

IsoBlock and IsoBand for Different Measurement Tasks

Depending on the product family, measurement range, galvanic isolation, bandwidth, and output signal vary. Many IsoBlock and IsoBand modules are designed for DIN-rail mounting. Depending on the sensor, measurement ranges extend from low currents to high-current applications and from low differential voltages into the kilovolt range.

Integrate Measurement Signals into DAQ Systems and Test Setups

For connection to data acquisition systems (DAQ), digitizers, and other measurement equipment, many Verivolt transducers provide scaled analog output signals. Galvanically isolated channels support measurements at different ground and common-mode potentials and simplify the design of multi-channel measurement systems.

Applications in Power Electronics, Battery Systems, and High Voltage

Typical applications include battery and energy storage systems, fuel cells, EV charging systems, variable frequency drives, motors, photovoltaics, and power electronics. For specialized applications, Verivolt also offers the IsoBlock Q-4c, a galvanically isolated signal amplifier for quench detection in superconducting magnets.

Skip product gallery

Similar items

Verivolt IsoBlock V-3P series | View: front right
Verivolt IsoBlock V-3P | Three-Phase Voltage Sensor

VV-ISOBLOCK-V-3P-Serie


Input Voltage: 150–1000 VAC, Bandwidth: up to 100 kHz, Accuracy: up to 0.1%

Price on request

Prices plus VAT
Verivolt IsoBand V  | view: front
Verivolt IsoBand V | Galvanically Isolated Voltage Transducer

VV-IsoBand-V-Serie


Input Range: ±5 to ±2000 V, Bandwidth: DC to 8 MHz, Isolation: 1500 V continuous / 5000 V peak

Regular price: €1,177.00
Prices plus VAT
Verivolt IsoBlock I-ZF-Series | view: front right
Zero Flux High Performance Current Sensor | IsoBlock I-ZF Series

VV-IsoBlock-I-ZF-Serie


Output voltage: 5 V / 10 V / 7 VAC, Input current: 20 A - 2000 A / 100 AAc - 2000 AAC

Price on request

Prices plus VAT
Verivolt IsoBlock V-1c - View front right
Verivolt IsoBlock V-1c | Differential Voltage Sensor

VV-ISOBLOCK-V-1C-Serie


Measurement Range: ±5 to ±1500 V, Bandwidth: DC to 100 kHz, Isolation: ±1500 V Continuous / 5000 V for 1 min

Regular price: From €320.00
Prices plus VAT