GW Instek PEL-3000E | Programmable Electronic DC Load
Test power supplies, chargers and batteries with realistic load profiles, identify protection thresholds and detect weaknesses early.
- ✓ 300 W load capacity
- ✓ 150 V/60 A or 500 V/15 A
- ✓ 25 µs Fast Sequence
from €1,707.00
€1,707.00
Prices plus VAT plus shipping costs
Programmable Electronic DC Load for Power Supply, Charger and Battery Testing
GW Instek PEL-3000 Series: Single-Channel Current Sinks for Test Benches
The PEL-3031E and PEL-3032E of the GW Instek PEL-3000 Series are programmable, single-channel electronic DC loads for testing power supplies, adapters, chargers, batteries and LED drivers.
Both models sink up to 300 W and measure voltage, current and power at the load input. As current sinks, they do not supply an output voltage and are not intended for load currents below 60 mA.
Dynamic Power Supply Testing and Load Sequences
In CC, CV, CR and CP mode, the models apply constant-current, constant-voltage, constant-resistance or constant-power load conditions.
Dynamic mode switches between two load conditions. Normal and Fast Sequences reproduce load profiles with up to 1,000 steps; Fast Sequence supports step times from 25 µs. This allows the output response of power supplies to be tested under defined load transients.
Battery Discharge and Protection Thresholds
Battery test automation terminates the discharge process based on input voltage, test duration or discharged capacity. OCP and OPP test routines increase current or power incrementally and determine the trip point of the protection circuit. Soft Start ramps the load current to the setpoint with an adjustable rise time.
Model Selection and Test System Integration
The PEL-3031E operates at up to 150 V and 60 A, while the PEL-3032E supports up to 500 V and 15 A; both models have a maximum power rating of 300 W.
Model selection of the
GW Instek PEL-3000 Series
depends on the DUT output voltage, required load current and minimum operating voltage. USB is included as standard, while GPIB and LAN are optional.
Trigger inputs and outputs synchronize sequences, while the analog control sets the load current via an external voltage or resistance.
Alternative Products
For fast load transients, multiple DUT outputs or a modular test setup, consider the ITECH IT8700P+ Series. For integrated fast-charging protocols and ripple measurement, the ITECH IT8500G+ Series is a suitable alternative. For load powers up to 3 kW, the ITECH IT8500+ Series is available.
Related Product Categories
Electronic Loads | Battery Measurement Technology | Bidirectional Power Supplies
Does the PEL-3000E Match Your Load Profile?
We compare voltage, load current, minimum operating voltage and sequence requirements with your DUT and determine whether the PEL-3031E or PEL-3032E is the right model.
Variants
Specifications
| Voltage range | 0 to 150 V for the PEL-3031E; 0 to 500 V for the PEL-3032E |
|---|---|
| Current range | 0 to 60 A for the PEL-3031E; 0 to 15 A for the PEL-3032E |
| Power range | 300 W per model |
| Minimum operating voltage | 1 V at 60 A and 0.5 V at 30 A for the PEL-3031E; 2.5 V at 15 A and 1.25 V at 7.5 A for the PEL-3032E |
| Application range | intended for constant-current load and measurement tasks from 60 mA |
| Operating modes | CC, CV, CR, CP, CC+CV, CR+CV and CP+CV |
| Dynamic mode | switching between two load conditions with separately adjustable levels, times and current slew rates |
| Maximum current slew rate | 2.5 A/ms for the PEL-3031E and 625 mA/ms for the PEL-3032E |
| Normal sequence | up to 10 sequences with 1,000 steps each and step times from 1 ms to 999 h 59 min 59 s |
| Fast sequence | one sequence with up to 1,000 steps and step times from 25 µs to 600 ms |
| Measurement functions | integrated voltage, current and power measurement at the load input |
| Battery discharge test | operation in CC, CR or CP mode with termination based on input voltage, test duration or discharged capacity |
| Battery discharge test limits | up to 999 h 59 min 59 s and 9,999.99 Ah |
| OCP/OPP test automation | step-by-step determination of overcurrent and overpower protection trip thresholds |
| Soft Start | adjustable rise time for controlled ramping to the current, resistance or power setpoint |
| Remote Sense | separate sense leads for voltage measurement directly at the DUT terminals |
| VON Voltage and VON Latch | voltage-dependent activation and deactivation of the load with a selectable latch function |
| Timer functions | elapsed-time display and automatic load shut-off after a preset duration |
| External setpoint control | load-current control via 0 to 10 V or 0 to 10 kΩ, proportional or inverse |
| Analog inputs and outputs | external control, current monitor output and status signals via the rear-panel J1 connector |
| Trigger connections | rear-panel BNC input and output for synchronizing dynamic tests and sequences |
| Protection functions | OVP, OCP, OPP, OTP, RVP and UVP |
| Preset memory | 10 data sets for instrument settings |
| Interfaces | USB as standard, GPIB and LAN optional, RS-232 available as a factory-installed option only |
| Dimensions and weight | 213.8 × 124.0 × 400.5 mm; approximately 7.5 kg |
Options & Accessories
| GTL-248 | GPIB cable,2.0m |
|---|---|
| GTL-246 | USB cable, Type A – Type B |
| PEL-010 | Dust Filter |
| PEL-004 | GPIB option |
| PEL-018 | LAN Card |
| GRA-414-J | Rack Mount Kit (JIS) |
| GRA-414-E | Rack Mount Kit (EIA) |
Scope of Delivery
| User manual /programming manual CD |
| Quick Start Guide |
| Power cord (region dependent) |
| 2 x Front terminal washers- spring washer (M6) |
| Remote sense cables, red/black (GTL-105A) |
Videos
Links & Downloads
Available Documents (Subject to Change)
Supplier
Founded in 1975, Good Will Instrument Co., Ltd was the first professional manufacturer in Taiwan specializing in electrical test & measurement instruments. GW Instek began as a manufacturer of power supplies and quickly expanded into the development of high precision electronic test and measurement instruments.