ITECH IT8200 | Regenerative AC/DC Electronic Load
Regenerative AC/DC load for precise, energy-efficient load testing with high power density and energy feedback to the grid.
- ✓ Power: up to 165 kVA
- ✓ Voltage: 350 V
- ✓ Power: up to 990 A
Regenerative AC/DC Electronic Load, High Power Density: 15 kVA in a 3U Unit, 6 kVA in a 1U/2U Unit
ITECH IT8200: DC Load and AC Load for Precise Testing
The ITECH IT8200 Series is a state-of-the-art DC electronic load and, at the same time, a high-performance AC load that sets new benchmarks in electrical test and measurement. With the ability to reproduce demanding load profiles realistically, the series enables reliable analysis of DC loads, DC signals, and AC/DC tests in AC operation.
As a programmable solution, it provides precise control of voltage, current, and load behavior.
With extensive accessories, compatible AC sources and DC sources, and seamless system integration, it can be flexibly integrated into modern test environments and reliably supports demanding applications.
Electronic DC Load with AC/DC Circuit Models
As a versatile electronic DC load, the IT8200 Series enables accurate simulation of circuits in DC and AC operation. Its electronic architecture supports different topologies such as single-phase rectifier RLC circuits and parallel RLC circuits, creating precise conditions for demanding tests.
With comprehensive test functions, both products and complete systems can be analyzed efficiently and reproducibly. The series delivers programmable flexibility, high efficiency, and stable test performance, making it ideal for AC/DC applications in laboratories and industrial environments.
Regeneration: High-Efficiency Power Feedback
A key feature of the IT8200 Series is regenerative power feedback. This electronic technology with integrated mains regeneration not only reduces energy and cooling costs, but also lowers the environmental footprint. The DC electronic load operates fully regeneratively and reliably feeds energy back into the grid in both AC and DC operation.
This makes the series, combined with stable power sources and existing DC power supplies, a future-ready solution that brings precision, sustainability, and high power to any AC/DC test environment.
Alternative Products
If you are looking for an AC/DC load without regenerative capability, the ITECH IT8600 Series is a suitable alternative with up to 14.4 kVA and an integrated oscilloscope, but without the energy recovery offered by the IT8200 Series. Do you need significantly higher power for DC load testing only? Then we recommend the ITECH IT8000 Series, a regenerative DC load offering system power up to 2 MW and voltages up to 2250 V.
Related Product Categories
Do you want to make your load testing more energy-efficient and powerful?
The ITECH IT8200 Series combines precise AC/DC load testing with regenerative energy recovery. We will be happy to advise you on the right power class and configuration for your application.
Variants
Specifications
| Advanced SiC technology | for high efficiency |
|---|---|
| High power density | 15 kVA in a 3U chassis |
| Measurement of up to 16 parameters | including Vrms, Arms, Freq, CF, PF, UTHD, ITHD, ±Vpeak |
| Master/slave parallel connection, power up to 960 kVA | Up to 64 units can be connected in parallel (3U models) |
| Highly efficient energy regeneration | |
| Voltage | 350 V L-N |
| Selectable modes | single-phase, three-phase, reverse-phase |
| Rated voltage | can be extended to 200% in reverse-phase mode |
| Frequency range | 16–500 Hz |
| Arbitrary waveform simulation | |
| CSV file import supported | |
| Various built-in waveforms | |
| User-friendly operation | via touchscreen and intuitive interface |
| Standard interfaces | USB, CAN, LAN, Digital I/O |
| Optional interfaces | GPIB, analog, RS232 |
| DC mode supports 9 operation modes | including CC, CR, CP, and CV |
| AC mode supports multiple modes | CC, CP, CR, CS, CC+CR, CE |
| CE mode simulates topologies | such as single-phase rectifier RLC and parallel RLC |
| AC mode supports both rectified and non-rectified operation | |
| Adjustable crest factor | 1.414 to 5.0 |
| Supports phase shift from -90° to +90.0° | After enabling rectification, the phase shift range is limited by the crest factor |
| Unity power factor function | allows the current waveform to follow the voltage waveform, keeping PF close to 1 |
| Three-phase mode | supports Y and Δ configurations |
| Comprehensive harmonic measurement and analysis | up to the 50th order |
| Built-in IEC 61000-3-2/3-12 pre-compliance test standard | Analysis of voltage/current harmonics, simulation of current harmonics, fundamental frequency ≤ 60 Hz |
| Supports charge/discharge phase angle control | from 0° to 359° |
| Multiple protection features | Protect Auto Clear (UV and FE), POVP, POCP, UVP, software watchdog |
| Supports CANopen, Modbus, LXI, SCPI, and other protocols |
Options & Accessories
| IT cabinet 15U/27U/37U | |
|---|---|
| AC power cord | 5 m |
| USB cable | for communication via the front USB port |
| IT-E177 | RS232 and analog interface |
| IT-E176 | GPIB interface |
| IT-E33620-OO | Test cable, 360 A/200 cm, round clamp to round clamp, black/red |
| IT-E32410(20)-OO | Test cable, 240 A/100 cm, round clamp to round clamp, black/red |
| IT-E31220-OO | Test cable, 120 A/200 cm, round clamp to round clamp, black/red |
| IT-E30615-OO | Test cable, 60 A/150 cm, round clamp to round clamp, black/red |
| IT-E30312(20)-YY | Test cable, 30 A/120 cm, Y-clamp to Y-clamp, black/red |
| IT-E168 | Fiber-optic kit for parallel operation (cabinet) |
| IT-E169 | Fiber-optic kit for parallel operation (single unit) |
| IT-E9003 | ITECH warranty up to 3 years |
| IT-E9005 | ITECH warranty up to 5 years |
Scope of Delivery
| Unit(s) of the IT8200 Series |
| Power cable |
| Factory test report |
| Operating instructions |
Applications
| Renewable Energy |
| Electromobility |
| Power Electronics |
| Electronic Components |
| Research and Development |