ITECH IT-M3400 | Bidirectional Programmable DC Power Supply
Bidirectional DC power supply for compact battery and module tests with energy recovery.
- ✓ Power: up to 14.4 kVA
- ✓ Voltage: 50 - 420 V
- ✓ Current up to 30 A
Prices plus VAT plus shipping costs
Bidirectional DC Power Supply for Battery, DC/DC Converter, and Automotive Testing
ITECH IT-M3400: When the DUT Absorbs and Returns Energy
In battery, DC/DC converter, and automotive testing, power often flows in both directions. The ITECH IT-M3400 Series is designed for exactly this task: it operates as a DC source and then absorbs energy again as a regenerative sink. In standalone operation, it switches quickly and seamlessly between source and sink. This enables charge and discharge cycles as well as bidirectional DC/DC testing with a single instrument.
Choosing the right model primarily depends on the DUT voltage and power requirements. The twelve models cover 60, 150, 300, or 600 V and power ratings of 200, 400, or 800 W; depending on the voltage range, currents of up to ±30 A are available. In sink operation, the IT-M3400 feeds up to 90% of the absorbed power back into the grid. This reduces heat dissipation in the test system, especially during repetitive charge and discharge cycles.
Different battery states can also be simulated without relying solely on actual charge cycles. With the optional BSS2000 software, voltage, capacity, internal resistance, and SOC can be defined, while actual charge and discharge curves can be imported from CSV files. For parallel test applications, the series can be expanded to systems with up to 256 independently configurable and synchronously controlled channels.
Alternative Products
If 800 W is not sufficient, the ITECH IT-M3900B Series extends the same concept into higher power ranges. For test systems with significantly higher DC power requirements, the ITECH IT6000C Series is a suitable choice.
Related Product Categories
Bidirectional Devices | Power Supplies and Sources | Loads
Which IT-M3400 Device Fits Your Test Channel?
Share your voltage range, maximum source/sink current, power, channel count, and interfaces. We will match them to the right model—or explain when a higher-power series is the better technical fit.
Variants
Specifications
| Device concept | bidirectional DC power supply with regenerative sink function |
|---|---|
| Output ranges | depending on the model, 60 V / ±30 A, 150 V / ±12 A, 300 V / ±6 A, or 600 V / ±3 A; 200 W, 400 W, or 800 W |
| Energy recovery | up to 90% of the absorbed power is fed back into the grid |
| Source/sink operation | fast and seamless transition between source and sink in standalone operation |
| Battery simulation | voltage, capacity, internal resistance, and SOC adjustable; simulation of up to 99 batteries in series and parallel configurations |
| Multi-channel control | up to 256 channels can be configured independently and controlled synchronously |
| Parallel operation | up to 16 units; sink operation and battery simulation are not available in parallel mode |
| Control modes | CC and CV priority with programmable voltage and current rise and fall times |
| Output impedance | adjustable for simulating battery internal resistance |
| Precharge function | prevents DC load current overshoot |
| Protection functions | OCP, UCP, OVP, UVP, OPP, OTP, Foldback, grid fault, power-off, and Sense fault protection |
| Form factor | 1U, half-rack width |
Options & Accessories
| IT-E118 | anti-reverse connection module for DC and Sense terminals |
|---|---|
| IT-E1203 | temperature sensor for measuring DUT temperature |
| IT-E1205 | GPIB interface card |
| IT-E1206 | USB/LAN interface card |
| IT-E1207 | RS-232/CAN interface card |
| IT-E1208 | interface card for external analog signals and RS-485 |
| IT-E1209 | USB interface card |
| IT-E154(A, B, C, D) | rack-mount accessories, depending on the installation configuration |
| IT-E30110-AB | test lead, 10 A, 1 m, alligator clip/banana plug |
| IT-E30110-BB | test lead, 10 A, 1 m, banana plug/banana plug |
| IT-E30110-BY | test lead, 10 A, 1 m, banana plug/Y terminal |
| IT-E30312(20)-YY | power cable, 30 A, 1.2 m or 2 m, Y terminals, supplied as a pair |
| IT-E30615-OO | power cable, 60 A, 1.5 m, ring terminals, supplied as a pair |
| IT-E31220-OO | power cable, 120 A, 2 m, ring terminals, supplied as a pair |
| IT-E32410(20)-OO | power cable, 240 A, 1 m or 2 m, ring terminals, supplied as a pair |
| IT-E33620-OO | power cable, 360 A, 2 m, ring terminals, supplied as a pair |
| IT-E9003 | warranty extension up to 3 years |
| IT-E9005 | warranty extension up to 5 years |
| BSS2000 | battery simulation software with characteristic curves, MATLAB models, and CSV charge/discharge curves |
| FCS3000 | fuel cell simulation software |
| ITS5300 | battery test software for charge/discharge, capacity, DC internal resistance, cycle life, temperature, and reliability testing |
| IT cabinet | system cabinet with 15U, 27U, or 37U |
Scope of Delivery
| Instrument | ITECH IT-M3400 Series in the selected model configuration |
|---|---|
| AC power cord | country-specific version |
| IT-E251 | interconnection cable for multi-unit operation |
| Factory test report | documentation of the instrument test performed prior to delivery |
Applications
| Battery testing | charging, discharging, battery simulation, and testing of smaller battery systems |
|---|---|
| Power modules | DC/DC converters, bidirectional DC/DC converters, DC/AC converters, and microinverters |
| Automotive electronics | power supply testing, including electric steering and braking systems |
| Industrial electronics | testing of UAV controllers, servo motors for small robots, and other intelligent industrial equipment |
Videos
Links & Downloads
Available Documents (Subject to Change)
Supplier
LXinstruments has been supplying ITECH equipment since 2020. When an individual instrument needs to become part of a complete test system, we support you with product selection, system sizing and integration into the automation environment. The key is to ensure that the DUT, power requirements, interfaces and test sequence work together.
We also use ITECH equipment in customized test systems. Depending on the test application, we combine power supplies, electronic loads, grid simulation and measurement technology so that the functions match both the DUT and the test sequence.