ITECH IT-M3900B | Bidirectional DC Source/Load System
Sources and loads DUTs in one system, returns energy to the grid, and accelerates dynamic testing with lower cooling and space requirements.
- ✓ Voltage: up to 1500 V
- ✓ Current: up to 1020 A (Source) / up to 720 A (Load)
- ✓ Power: up to 12 kW
Prices plus VAT plus shipping costs
Regenerative DC Source/Load System
ITECH IT-M3900B: Source/Sink Operation for Dynamic DC Test Profiles
The ITECH IT-M3900B Series combines a bidirectional DC power supply with a regenerative electronic DC load. With up to 6 kW in 1 U, 12 kW in 2 U, 1,500 V, and 1,020 A, compact DC test systems with high power density can be configured.
The IT-M3900B supplies and loads DUTs with a single instrument. In load operation, according to the manufacturer, up to 95% of the absorbed power is fed back into the grid. Fast current direction switching reduces overshoot during dynamic testing. CV/CC priority, adjustable output impedance, and programmable voltage, current, and power slew rates support changing operating points. Up to 10 million sequence points as well as CC, CV, CW, CR, and combined operating modes enable complex test sequences.
Battery Testing, Scalability and System Integration
Battery tests and simulations can be parameterized using voltage, capacity, internal resistance, and state of charge. Stored test curves support selected requirements according to LV123, LV148, DIN 40839, ISO 16750-2, SAE J1113-11, LV124, and ISO 21848; 10 V models are excluded. Master-slave parallel operation increases the available power. USB, CAN, LAN, and Digital I/O are integrated; GPIB and Analog/RS-232 are optional. OVP, ±OCP, ±OPP, as well as overtemperature, voltage-drop, and anti-islanding protection ensure safe operation.
Alternative Products
If your test system requires a dedicated high-power DC supply, the ITECH IT6600D Series provides high DC power in a compact form factor. If you need to apply regenerative loads to both AC and DC DUTs and feed energy back into the grid, the ITECH IT8200E Series is the suitable AC/DC load.
Related Product Categories
Bidirectional Devices | Electronic Loads | Power Supplies and Sources
Would you like to integrate the ITECH IT-M3900B Series into your test system or need support in selecting the right configuration?
Contact us – we will assist you in optimizing system design and integration into your test environment.
Variants
Specifications
| Reverse-polarity protection modules |
|
|---|---|
| IT-E165B | Anti-EMF protection module, 1,200 V / 200 A, for preventing reverse current from the DUT |
| Parallel operation | IT-E168/IT-E169 fiber-optic kits for optical connection in parallel configurations |
| Rack mounting | IT-E155A, IT-E155B, and IT-E155C for rack installation of 1 U units |
| Interfaces |
|
| Battery simulation | BSS2000 battery simulation software |
| PV simulation | SAS1000 software for simulating solar arrays and I-V characteristics |
| Fuel cell simulation | FCS3000 software for single-channel fuel cell simulation |
| System cabinets |
|
| AC power cord | optional 5 m power cord for system cabinets, depending on configuration |
| Test leads |
|
| IT-E9003 | ITECH warranty up to 3 years |
| IT-E9005 | ITECH warranty up to 5 years |
Options & Accessories
| IT-E165A-250 | reverse-polarity protection unit, 750 V / 250 A |
|---|---|
| IT-E165A-400 | reverse-polarity protection unit, 750 V / 400 A |
| IT-E165A-500 | reverse-polarity protection unit, 900 V / 400 A |
| IT-E165B | anti-EMF unit, 1,200 V / 200 A, for reverse-current protection |
| IT-E168/IT-E169 | fiber-optic interconnection kit for parallel operation of multiple units |
| IT-E155A | 1U rack-mount kit |
| IT-E155B | supplementary 1U rack-mount kit for use with IT-E155A |
| IT-E155C | supplementary 1U rack-mount kit for use with IT-E155A |
| IT-E176 | GPIB communication interface |
| IT-E177 | combined RS-232/analog communication card |
| BSS2000 | battery simulation software |
| SAS1000 | software for PV array and I-V curve simulation |
| FCS3000 | software for single-channel fuel cell simulation |
| IT-E510-15U | system cabinet, 15U, gray, 800 × 550 × 907.64 mm |
| IT-E511-15U | system cabinet, 15U, black, 800 × 550 × 907.64 mm |
| IT-E510-27U | system cabinet, 27U, gray, 800 × 600 × 1,441.41 mm |
| IT-E511-27U | system cabinet, 27U, black, 800 × 600 × 1,441.41 mm |
| IT-E510-37U | system cabinet, 37U, gray, 800 × 600 × 1,885.91 mm |
| IT-E511-37U | system cabinet, 37U, black, 800 × 600 × 1,885.91 mm |
| IT-E258-15U | 5 m AC power cord for 15U system cabinets, Chinese standard |
| IT-E258-27U | 5 m AC power cord for 27U system cabinets, Chinese standard |
| IT-E258-37U | 5 m AC power cord for 37U system cabinets, Chinese standard |
| USB cable | connection cable for USB communication |
| AC power cord | model-dependent mains connection cable |
| IT-E30110-AB | test lead, 10 A, 1 m, alligator clip to banana plug |
| IT-E30110-BB | test lead, 10 A, 1 m, banana plug to banana plug |
| IT-E30110-BY | test lead, 10 A, 1 m, banana plug to Y terminal |
| IT-E9003 | ITECH warranty extension for up to 3 years |
| IT-E9005 | ITECH warranty extension for up to 5 years |
Scope of Delivery
| Device(s) of the IT-M3900B Series |
| Power cord |
| USB communication cable |
| Factory test report |
| Operating manual |
Applications
| Battery testing and battery simulation |
| Automotive power electronics and automotive testing |
| Industrial power supplies, UPS, and HVDC systems |
| Small and medium-power motor drives |
| PV and solar array simulation |
| Fuel cell simulation |
Videos
Links & Downloads
Available Documents (Subject to Change)
Supplier
LXinstruments has been supplying ITECH equipment since 2020. When an individual instrument needs to become part of a complete test system, we support you with product selection, system sizing and integration into the automation environment. The key is to ensure that the DUT, power requirements, interfaces and test sequence work together.
We also use ITECH equipment in customized test systems. Depending on the test application, we combine power supplies, electronic loads, grid simulation and measurement technology so that the functions match both the DUT and the test sequence.