ITECH IT-M3900C | Bidirectional DC Source and Load
Sources and sinks power bidirectionally, returns energy to the grid, and simplifies dynamic testing in compact test systems.
- ✓ Voltage: up to 1500 V
- ✓ Current: up to 1020 A
- ✓ Power: ±12 kW
Prices plus VAT plus shipping costs
Programmable Bidirectional DC Power Supply with Regenerative Energy Feedback
ITECH IT-M3900C: DC Source and Regenerative Load for Dynamic Testing
The ITECH IT-M3900C Series combines a bidirectional DC power supply with a regenerative electronic DC load. Depending on the model, the series provides up to 1,500 V, a current range of up to +1,020 A / -720 A, and up to ±12 kW. The wide-range output enables different voltage and current combinations with a single instrument.
The IT-M3900C supplies and loads DUTs with seamless switching between source and sink operation, reducing voltage and current overshoot. Up to 95% of the absorbed power is fed back into the grid. CV/CC priority, adjustable output impedance, and up to 10 million points for dynamic test curves support reproducible battery, DC-DC, and automotive testing.
Battery models can be defined using voltage, capacity, internal resistance, and state of charge. Depending on the model and software, the series also supports PV simulation, fuel cell simulation, and master-slave parallel operation for higher system power.
Alternative Products
For bidirectional DC testing with lower power requirements, the ITECH IT-M3400 Series is suitable. For higher system power, the ITECH IT6000C Series and the ITECH IT6600C Series are available as regenerative bidirectional DC power supplies.
Related Product Categories
Bidirectional Devices | Electronic Loads | Power Supplies and Sources
Does the IT-M3900C Match Your Bidirectional Test Profile?
We review voltage, current, power, regeneration, dynamics, parallel operation, and interfaces with you to ensure the configuration fits your DUT and test system.
Variants
Specifications
| Device concept | bidirectional programmable DC power supply and regenerative electronic DC load in a single instrument |
|---|---|
| Power and form factor |
|
| Voltage range | model-dependent from 10 V to 1,500 V |
| Current range | model-dependent from -720 A to +1,020 A |
| Regenerative energy feedback | up to 95% of the absorbed power fed back into the utility grid with automatic grid detection |
| Bidirectional operation | seamless switching between source and sink operation to reduce voltage and current overshoot |
| Wide-range output | different voltage and current combinations within the respective power limit |
| Operating modes |
|
| Control |
|
| Battery functions |
|
| Dynamic test profiles |
|
| Automotive test curves | built-in curves for LV123, LV148, DIN 40839, ISO 16750-2, SAE J1113-11, LV124, and ISO 21848, excluding 10 V models |
| PV simulation | I-V curve simulation for 85 V SAS and 150 V PV models |
| Parallel operation | master-slave parallel operation for power expansion; not recommended for PV simulation |
| Interfaces |
|
| Protection functions |
|
Options & Accessories
| IT-E165A-250 | Reverse-polarity protection module, 750 V / 250 A |
|---|---|
| IT-E165A-400 | Reverse-polarity protection module, 750 V / 400 A |
| IT-E165A-500 | Reverse-polarity protection module, 900 V / 400 A |
| IT-E165B | Anti-EMF protection module, 1,200 V / 200 A, for preventing reverse current from the DUT |
| IT-E168/IT-E169 | Fiber-optic kits for parallel operation |
| IT-E176 | GPIB communication interface |
| IT-E177 | RS-232 and Analog communication interface |
| BSS2000 | Battery simulation software |
| SAS1000 | Software for solar array and I-V curve simulation |
| FCS3000 | Single-channel fuel cell simulation software |
| IT-E155A/IT-E155B/IT-E155C | Rack mounting kits for different 1 U installation configurations |
| IT-E510-15U / IT-E511-15U | 15 U system cabinet, grey or black |
| IT-E510-27U / IT-E511-27U | 27 U system cabinet, grey or black |
| IT-E510-37U / IT-E511-37U | 37 U system cabinet, grey or black |
| IT-E258E-15U | 5 m AC input power cord for 15 U system cabinet, EU standard |
| IT-E258E-27U | 5 m AC input power cord for 27 U system cabinet, EU standard |
| IT-E258E-37U | 5 m AC input power cord for 37 U system cabinet, EU standard |
| IT-E33620-OO | High-current test cable pair, 360 A / 2 m, round terminals |
| IT-E32410-OO | High-current test cable pair, 240 A / 1 m, round terminals |
| IT-E32420-OO | High-current test cable pair, 240 A / 2 m, round terminals |
| IT-E31220-OO | High-current test cable pair, 120 A / 2 m, round terminals |
| IT-E30615-OO | High-current test cable pair, 60 A / 1.5 m, round terminals |
| IT-E30312-YY | Test cable pair, 30 A / 1.2 m, Y terminals |
| IT-E30320-YY | Test cable pair, 30 A / 2 m, Y terminals |
| IT-E30110-AB | Test cable pair, 10 A / 1 m, alligator clip to banana plug |
| IT-E30110-BB | Test cable pair, 10 A / 1 m, banana plug to banana plug |
| IT-E30110-BY | Test cable pair, 10 A / 1 m, banana plug to Y terminal |
| IT-E9003 | ITECH warranty extension up to 3 years |
| IT-E9005 | ITECH warranty extension up to 5 years |
Scope of Delivery
| Device(s) of the IT-M3900C-Series |
| 1 x Power cord |
| 1 x USB communication cable |
| 1 x Factory test repor |
| 1 x Operating manual |
Applications
| IT-M3900C Series unit(s) |
| 1 x AC power cord |
| 1 x factory test report |
| 1 x operating manual |
| 1 x USB cable |
Videos
Links & Downloads
Available Documents (Subject to Change)
Supplier
LXinstruments has been supplying ITECH equipment since 2020. When an individual instrument needs to become part of a complete test system, we support you with product selection, system sizing and integration into the automation environment. The key is to ensure that the DUT, power requirements, interfaces and test sequence work together.
We also use ITECH equipment in customized test systems. Depending on the test application, we combine power supplies, electronic loads, grid simulation and measurement technology so that the functions match both the DUT and the test sequence.