ITECH IT7900EP | High Performance Regenerative Grid Simulator
Regenerative grid simulation and AC/DC load in one system – for reproducible power tests up to 1 MVA.
- ✓ Power: 21 to 126 kVA · up to 1 MVA in parallel
- ✓ Output: up to 350 V L-N · 606 V L-L
- ✓ Frequency: 16 Hz to 2.4 kHz
Prices plus VAT plus shipping costs
Regenerative Grid Simulator for Grid Simulation, AC/DC Testing and PHiL
ITECH IT7900EP: Simulate Grid Events and AC/DC Conditions in a Controlled Manner
The ITECH IT7900EP Series is a regenerative grid simulator for PCS, energy storage systems, microgrids, and grid-connected power electronics. In four-quadrant AC/DC operation, it supplies power, absorbs energy from the DUT, and feeds it back into the grid.
Flexible Grid Simulation for AC, DC and Mixed Signals
Harmonic and interharmonic synthesis, anti-islanding, and Low Voltage Ride Through simulate defined grid events. The AC, DC, AC+DC, and DC+AC output modes cover conventional grid simulation as well as testing with DC or combined AC/DC signals. This makes it possible to evaluate how systems respond to changing supply and grid conditions.
Scalable Power into the Megawatt Range
The series covers 21 to 126 kVA and can be expanded to 1 MVA and above using master-slave operation. Up to 350 V AC L-N or 606 V AC L-L support low-voltage grids and industrial test applications. In sink operation, energy is fed back into the grid instead of being dissipated as heat. In Power Hardware in the Loop (PHiL) applications, the IT7900EP operates as a power amplifier between the simulation environment and the physical DUT.
Alternative Products
For power levels below 21 kVA, the ITECH IT7900P is suitable; for applications without additional load functionality, the ITECH IT7900 is an alternative.
Related Product Categories
Simulators | Power Supplies / Sources | Bidirectional Devices | Electronic Loads
Select the IT7900EP Series to Match Your Test Task
Together with you, we configure the ITECH IT7900EP Series to match your devices under test, grid events, and test procedures. The result is a powerful test setup that allows you to define grid conditions reproducibly and map demanding test tasks reliably.
Variants
Specifications
| SiC Technology | Fast, efficient, and precise control |
|---|---|
| Power Density | Up to 21 kVA in just 3U |
| Output Voltage | Up to 350 V L-N |
| Power Expansion | Parallel operation up to 1 MVA |
| Energy Regeneration | Efficiently feeds energy back to the grid |
| Operating Modes | Single-phase, three-phase, and switchable phase sequence |
| Voltage Extension | Up to 200% of rated voltage in inverter operation |
| Simulation Modes | LIST, SWEEP, and Surge & Sag |
| Waveform Library | Many standard waveforms integrated |
| Harmonics | current harmonic simulation) |
| Arbitrary Function | Freely definable waveforms |
| Waveform Import | Import custom waveforms via CSV |
| Phase Angle | Freely adjustable from 0 to 360° |
| Operation | Color touchscreen with simple menu navigation |
| Standard Interfaces | USB, CAN, LAN, and Digital I/O integrated |
| Optional Interfaces | GPIB, analog interface, and RS232 |
| Protection Functions | Auto-Clear, POVP, and Watchdog |
| Communication Protocols | CANopen (please inquire), Modbus, LXI, and SCPI |
Specifications in Source Operation
| Frequency Range | 16 Hz to 2400 Hz |
|---|---|
| PHiL Function | Power amplifier for PHiL applications |
| Output Modes | AC, DC, AC+DC, DC+AC |
| Output Impedance | Programmable |
| Harmonics | Harmonic and interharmonic generation |
| Test Functions | LVRT, phase jump, frequency variation, harmonic injection |
| Test Standards | IEC 61000-4-11, IEC 61000-4-13, IEC 61000-4-14, IEC 61000-4-17, IEC 61000-4-28, IEC 61000-4-29 |
Specifications in Load Operation
| Device Function | Regenerative 4-quadrant AC/DC load |
|---|---|
| Frequency Range | 16 Hz to 500 Hz |
| AC Operating Modes | CC, CP, CR, CS, CC+CR, CE |
| CE Mode | Simulation of rectifier RLC and parallel RLC topologies |
| DC Operating Modes | 9 modes, including CC, CR, CP, and CV |
| AC Modes | Rectifying and non-rectifying |
| Crest Factor | 1.414 to 5.0 |
| Phase Shift | -180° to 180° (when the rectifier function is enabled, the phase shift range is limited by the crest factor) |
| Power Factor 1 Function | Current waveform follows voltage waveform |
| Switching Angle | Adjustable from 0 to 359° |
Options & Accessories
| IT-E510-15U | Rack kit, 15U, gray |
|---|---|
| IT-E511-15U | Rack kit, 15U, black |
| IT-E510-27U | Rack kit, 27U, gray |
| IT-E511-27U | Rack kit, 27U, black |
| IT-E510-37U | Rack kit, 37U, gray |
| IT-E511-37U | Rack kit, 37U, black |
| IT-E31220-OO | Test lead 120 A/200 cm, ring terminal -> ring terminal, black/red |
| IT-E32410-OO | Test lead 240 A/100 cm, ring terminal -> ring terminal, black/red |
| IT-E32420-OO | Test lead 240 A/200 cm, ring terminal -> ring terminal, black/red |
| IT-E33620-OO | Test lead 360 A/200 cm, ring terminal -> ring terminal, black/red |
| AC power cord | length 5 m |
| IT-E168 | Fiber optic kit for parallel operation of individual units |
| IT-E169 | Fiber optic kit for parallel operation of cabinets |
| IT-E176 | GPIB interface |
| IT-E177 | Analog & RS232 interface |
| IT-E9003 | ITECH extended warranty |
| IT-E9005 | ITECH extended warranty |
Scope of Delivery
| IT7900EP series unit(s) |
| Power cord |
| USB cable |
| LAN cable |
| Operating manual |
| Factory test report |
Applications
| Grid simulation |
| Energy storage |
| Photovoltaics |
| IEC testing |
| Laboratory, research, development, and certification |
| Education and training |
Links & Downloads
Available Documents (Subject to Change)
Supplier
LXinstruments has been supplying ITECH equipment since 2020. When an individual instrument needs to become part of a complete test system, we support you with product selection, system sizing and integration into the automation environment. The key is to ensure that the DUT, power requirements, interfaces and test sequence work together.