VTI Instruments EX1200 Series – High-Density Switching and Data Logger Mainframe

For precise switching and measurement in a single system

The VTI Instruments EX1200 Series is a high-density, modular switching and data logger mainframe with 2 to 16 slots, an internal 5-wire bus, and an LXI interface. It provides maximum flexibility for Test Data Acquisition, development, production, and service applications, while precise hardware handshaking ensures reliable and repeatable measurement results.

Highest Channel Density and Modular Architecture

The EX1200 Series is the highest-density switching and data acquisition system on the market. It combines low-level, power, and RF switching modules in a single mainframe and provides a flexible hardware and software platform. This allows the creation of a complete switching and measurement system, easily expanded with precise analog and digital I/O for a wide range of test applications.

Integrated Digital Multimeter for Precise Data Acquisition

With the optional 6.5-digit digital multimeter (DMM), the EX1200 Series becomes a cost-efficient measurement and control solution. Plug-in modules such as multiplexers, analog and digital outputs, or speed/rotation signal inputs expand the system for diverse measurement tasks, including external device control and the analysis of rotating machinery.

More Workspace and Superior

Signal Integrity Compared to PXI systems, the EX1200 Series offers nearly twice the usable workspace and higher channel capacity within the same footprint. This ensures excellent signal integrity, even in complex applications. For lower-density requirements, VTI Instruments also offers a wide range of high-performance PXI Express modules.

Minimal Loss, Maximum Data Quality

The performance of a switching system is determined not only by relays and circuit boards, but also by cables and connectors. The EX1200 Series ensures optimized signal routing with minimal loss, maximum stability, and user-friendly connection options – guaranteeing clean signals and the highest possible data quality.

Switching and Data Logger System for Every Application

The VTI Instruments EX1200 Series is the ideal choice for organizations that require a scalable, high-density, and precise switching and data acquisition system. Whether in the lab, production line, or field service, this mainframe delivers maximum flexibility, superior signal integrity, and long-term investment protection

Interfaces: LAN (Ethernet, LXI Class A)
Signal type: Current, Digital I/O, Frequency, Temperature, Voltage

Related links to "Switch and Data Logger Mainframe | EX1200 Series"

Available documents (Subject to change)

Specifications of the Switch and Data Logger Mainframe of the EX1200 Series

  • Universal and multiplexer switching: 300 V, 3 A, Power switching: up to 16 A, High-voltage switching: up to 1000 V
  • RTD simulator
  • Comparator / threshold detector
  • RF / microwave switching
  • Digital inputs and outputs
  • 2- to 16-slot mainframe
  • Front-pluggable modules
  • Switching / scanning up to 576 2-wire channels in 1U
  • Rugged connectors for long-lasting interface reliability
  • Fully featured 6.5-digit DMM*1,2
  • Internal 5-wire bus directly connected to the DMM
  • 8-wire LXI trigger bus
  • Digital I/O and alarm outputs
  • LAN/LXI status LEDs
  • Standard LAN connectivity
  • EXLab “Set Up and Run” software*1
  • Real-time handshaking via the LXI trigger bus
  • Integrated mass interconnect on plug-in modules
  • Rear access points for easy I/O interfacing
  • Web-based remote access

*1 optional
*2 comes with EX1262

Options and Accessories of the Switch and Data Logger Mainframe of the EX1200 Series

Pre-Assembled Cables:

  • 70-0363-506 41-pin, Unterminated Cable Assembly, length: 3 ft. (91,4 cm)
  • 70-0363-502 44-pin, Unterminated Cable Assembly, length: 3 ft. (91,4 cm)
  • 70-0363-501 104-pin, Unterminated Cable Assembly, length: 3 ft. (91,4 cm)
  • 70-0363-505 160-pin, Unterminated Cable Assembly, length: 3 ft. (91,4 cm)

Interface Test Adapters:

  • CMX24-XT, Integrated 18-slot PXI Express/EX1206A mainframe with pull-through receiver
  • CMX34-G18, Integrated 18 slot PXI Express/EX1208A mainframe, with cabled receiver

PXI Express Switch Modules:

  • smx-3276 76 channel, dual (1x38) 2-wire, 300V/2A multiplexer
  • smx-4410 160 crosspoint, four (4x10), 2-wire, 300V/2A matrix
  • smx-2002 12-channel, 16A, Form C (SPDT) switch
  • smx-5001 80-channel, 2A, Form A (SPST) switch
  • smx-6301 Four SP4T multiplexer tree, 3 GHz
  • smx-7x00 DC to 26.5 GHz, microwave switch carrier and relay drive

Scope of Delivery of the Switch and Data Logger Mainframe of the EX1200 Series

  • Unit(s) of the EX1200 Series

Applications Areas of the Switch and Data Logger Mainframe of the EX1200 Series

  • Power supply circuits
  • Temperature monitoring (RTDs, thermocouples, thermistors)
  • Automotive ECU testing
  • High-voltage monitoring
  • Data logging applications
  • Cable/harness testing
  • Battery testing
  • RTD/sensor simulation
  • Home appliance testing<

VTI Instruments, located in San Diego, provides products and systems which are used to monitor and record data that characterizes the physical integrity and performance of aircraft, engines, and other large structures, as well as automate the functional testing of complex electronic systems. VTI Instruments is recognized as an industry leader with a reputation of providing reliable data, first time, every time.