ITECH IT-N2100 | Solar Array Simulator
Evaluate MPPT behavior, efficiency, and function independently of weather and physical PV modules under repeatable conditions.
- ✓ Power: up to 1.5 kW
- ✓ MPPT Tracking: up to 250 Hz
- ✓ I-V Curve: up to 4.096 Data Points
Prices plus VAT plus shipping costs
ITECH IT-N2100 Solar Array Simulator for MPPT and PV Inverter Testing
PV Simulator for Static and Dynamic I-V Curves
The ITECH IT-N2100 is a programmable solar array simulator for reproducing static and dynamic I-V curves of PV modules and solar arrays. It enables microinverters, power optimizers, and PV inputs of energy storage systems to be tested independently of actual weather conditions. Irradiance, temperature, and shading can be simulated under controlled conditions for reproducible testing of MPPT tracking, MPPT efficiency, and device functionality.
The PV simulator supports MPPT tracking rates up to 250 Hz and accurately follows the specified I-V curve even during rapid operating-point changes. Table mode supports up to 4,096 data points. Static and dynamic shading curves can also be simulated. Low output current ripple helps minimize the influence of the source on current sampling and MPPT evaluation.
Five PV modes cover user-defined curves, LIST sequences, built-in models, fixed mode, and table mode. Tests according to EN 50530, Sandia, NB/T 32004, CGC/GF004, and CGC/GF035 can be performed and documented using the solar array simulation software. Up to 20 channels can be controlled synchronously. Depending on the model, output ratings of 80 V or 150 V, up to 25 A, and 800 W or 1,500 W are available.
Similar Products
For PV test applications with higher voltage, current, or power requirements, ITECH offers additional systems with solar array simulation. The ITECH IT6000B Series combines bidirectional source and load operation with PV I-V curve simulation using SAS1000. The ITECH IT6000C Series also supports PV simulation and is suitable for higher-power regenerative DC test systems.
Related Product Categories
Realistic PV Testing
From static I-V curves to fast MPPT tracking, the key is ensuring that the simulator and DUT are technically matched. We support you in selecting the appropriate IT-N2100 variant and configuring it for your PV test application.
Variants
Specifications
| Product class | solar array simulator and programmable DC power supply for simulating photovoltaic I-V curves |
|---|---|
| Models | IT-N2121, IT-N2123, IT-N2131, and IT-N2133 |
| Output power | model-dependent, 800 W or 1,500 W |
| Output voltage | model-dependent, 0 V to 80 V or 0 V to 150 V |
| Output current | model-dependent, up to 10 A or 25 A |
| 80 V models | output voltage expandable up to 85 V |
| Wide-range output | available on the 800 W models for different voltage and current combinations within the power limit |
| Current control loop | bandwidth up to 500 kHz |
| Supported MPPT tracking frequency | up to 250 Hz |
| Dynamic voltage response | model-dependent, 150 µs to 400 µs |
| Programming response time | ≤ 15 ms |
| I-V curves | up to 4,096 data points |
| PV operating modes | user-defined mode, curve mode, List Mode, fixed mode, and table mode |
| Four-point method | rapid curve generation using Voc, Isc, Vmp, and Imp |
| Fixed mode | CC, CV, and CP output behavior |
| Output impedance | adjustable from 0 Ω to 9.999 Ω on the 80 V models |
| PV cell models | simulation of I-V curves for silicon, GaAs, and other solar cell technologies |
| PV test models | EN 50530, Sandia, NB/T 32004, CGC/GF 004, and CGC/GF 035 |
| Dynamic PV simulation | up to 65,000 time points with 1 s time resolution |
| List Mode | up to 100 steps in 20 data sets |
| Shading simulation | static and dynamic I-V curves, including moving shading profiles |
| Environmental simulation | I-V curves under varying irradiance and temperature |
| Multi-channel control | synchronous control of up to 20 solar array simulators via the PV software |
| File management | create, upload, download, and store up to 100 I-V and PV files |
| Measurement logging | real-time acquisition of voltage, current, and power |
| Data export | CSV and TDMS files to USB storage devices |
| Report function | automatic generation of standardized test reports |
| Display | 4.3-inch HD LCD for graphical display of curves and MPPT status |
| Voltage resolution | 10 mV for setting and 1 mV for readback |
| Current resolution | 1 mA for setting and readback |
| Voltage setting accuracy | model-dependent, ≤ 0.03% + 20 mV or ≤ 0.03% + 30 mV |
| Current setting accuracy | model-dependent, ≤ 0.05% + 5 mA or ≤ 0.05% + 10 mA |
| Voltage ripple | ≤ 40 mV RMS |
| Current ripple | model-dependent, ≤ 5 mA RMS to ≤ 10 mA RMS |
| Rise and fall time | ≤ 20 ms each at no load and full load |
| Remote sense compensation | ≤ 2 V |
| Common-mode withstand voltage, output to ground | 1,500 V DC |
| Withstand voltage, input to ground | 1,500 V AC |
| AC input | 110 V or 220 V, 50/60 Hz |
| Maximum input current | 11 A |
| Power factor | ≥ 0.98 |
| Typical efficiency | 60% for 80 V models and 72% for 150 V models |
| Protection functions | OVP, OCP, OPP, and OTP |
| Standard interfaces | LAN, USB, and digital I/O; remote control via SCPI |
| Outputs | front- and rear-panel terminals |
| Form factor | 2U half-rack per channel |
| Rack-mount dimensions | 450 × 214 × 88.2 mm |
| Overall dimensions | 529.5 × 255 × 108.2 mm |
| Net weight | 9 kg |
| Cooling | forced-air cooling |
| Operating temperature | 0°C to 40°C |
| Degree of protection | IP20 |
| Safety requirements | IEC 61010 |
Options & Accessories
| IT system cabinet | system cabinet in 15U, 27U, or 37U |
|---|---|
| IT-E30305-IY | test lead pair, 1 m, I-type terminal to fork terminal |
| IT-E30615-OO | high-current cable pair, 60 A, 1.5 m, round terminal to round terminal |
| IT-E30312-YY | test lead pair, 30 A, 1.2 m, fork terminal to fork terminal |
| IT-E30320-YY | test lead pair, 30 A, 2 m, fork terminal to fork terminal |
| IT-E30110-AB | test lead pair, 10 A, 1 m, alligator clip to banana plug |
| IT-E30110-BB | test lead pair, 10 A, 1 m, banana plug to banana plug |
| IT-E30110-BY | test lead pair, 10 A, 1 m, banana plug to fork terminal |
| AC power cord | configuration-dependent mains connection cable |
| IT-E9003 | ITECH warranty extension for up to 3 years |
| IT-E9005 | ITECH warranty extension for up to 5 years |
Scope of Delivery
| IT-N2100 Series unit(s) |
| AC power cord |
| US connection cable |
| Calibration certificate |
Applications
| Static and dynamic MPPT testing of microinverters |
| Testing of PV power optimizers |
| Testing of multi-channel inverters and PV inputs |
| Simulation of solar modules and PV arrays under varying irradiance and temperature |
| Testing inverter behavior under partial shading and dynamic I-V curves |
| Development, verification, and production testing of PV inverters |
| Burn-in and endurance testing of photovoltaic power-conversion systems |
| Testing of PV-coupled home energy storage and power-supply systems |
| Testing of photovoltaic power-supply systems for aerospace applications |
Videos
Links & Downloads
Available Documents (Subject to Change)
Supplier
LXinstruments has been supplying ITECH equipment since 2020. When an individual instrument needs to become part of a complete test system, we support you with product selection, system sizing and integration into the automation environment. The key is to ensure that the DUT, power requirements, interfaces and test sequence work together.
We also use ITECH equipment in customized test systems. Depending on the test application, we combine power supplies, electronic loads, grid simulation and measurement technology so that the functions match both the DUT and the test sequence.