ITECH IT7900 Series
Programmable, regenerative 4-Quadrant AC Grid Simulator
Power: up to 165 kVA, Voltage: 350 V, Current: up to 990 A
The IT7900 series represents the latest generation of programmable four-quadrant grid simulators and can also be used to test various grid-connected equipments. The advanced SiC semiconductor technology provides high power density in a small footprint. The series offers 6 kVA in a 1U size. When connected in parallel in master/slave mode, the power can be extended up to 960 kVA. Various operating modes meet different test requirements from single-phase, three-phase, antiphase and multi-channel. In addition to supplying sensitive applications with precise alternating current, the IT7900 series is able to simulate distorted voltage waveforms, interference signals and grid faults.
Specifications of the programmable, regenerative Grid Simulator IT7900 series
- Voltage: 350 VL-N, (700/1050 VL-N)1
- Current: up to 990 A
- Power: up to 165 kVA
- With master/slave parallel connection, the power can be increased up to 960 kVA
- Power Amplifier function for PHiL applications (Power Hardware-in-the-Loop)
- Frequency: 16 Hz~150 Hz
- Compact design, 6 kVA in 1U
- Built-in interfaces: USB / CAN / LXI compliant LAN / digital I/O
- Optional interfaces: GPIB / Analog&RS232
- Efficient power regeneration
- Four output modes: AC, DC, AC+DC and DC+AC
- Working modes: CV / CC / CP
- Various waveforms (sine, square, triangle, trapezoid...)
- Import and export of data and waveforms via USB port on the front panel
- Intuitive touch screen; built-in single/3-phase AC power meter; scope function
- Settable phase angle, 0...360°
- Fast response time and high accuracy 0.1 % + 0.2 % FS
- Harmonics and interharmonics waveform synthesizer
- Measurement function up to the 50th harmonic of voltage and current
- Relay CTRL function, to cut off the connection between power supply and DUT
- Supported regulatory testing include IEC 61000-4-11 / 4-13 / 4-14 / 4-28
- ATE models without touchscreen
Applications of the programmable, regenerative Grid Simulator IT7900 Series
Related links to "Regenerative grid simulator | IT7900 Series"
Available documents (Subject to change)
Options & accessories of the programmable, regenerative grid simulator IT7900 Series
| Model | Description |
| IT-E176 | GPIB communication card |
| IT-E177 | RS232- and analog communication card |
| IT-E168 | Optical Fiber Set |
| IT-E169 | Optical Fiber for paralleling between cabinets |
| IT-E30312 | Test cable, 30 A / 1.2 m, forked cable lug, red / black |
| IT-E30615 | Test cable, 60 A / 1.5 m, ring cable lug, red / black |
| IT-E31220 | Test cable, 120 A / 2 m, ring cable lug, red / black |
| IT-E32410 | Test cable, 240 A / 2 m, ring cable lug, red / black |
| IT-E33620 | Test cable, 360 A / 2 m, ring cable lug, red / black |
Scope of delivery of the programmable, regenerative grid simulator IT7900 Series
- Unit of the IT7900 series
- Power cord
- Factory test report
- USB communication cable
- Operating manual