ITECH IT7800 | Programmable AC/DC Power Supply
Simulate AC/DC supply, grid disturbances, and inrush behavior under realistic conditions in R&D, validation, and production.
- ✓ Power up to 165 kVA/960 kVA parallel
- ✓ Frequency 16 Hz to 2.4 kHz
- ✓ Output modes AC/DC/AC+DC/DC+AC
Programmable AC/DC Power Supply for Grid Simulation, UPS, and Frequency Converter Tests
ITECH IT7800: AC/DC Test Conditions for Lab, Validation, and Production
The ITECH IT7800 Series is a programmable AC/DC power supply for supply and functional tests on frequency converters, UPS systems, AC motors, AC-DC power supplies, OBCs, and AC/DC charging stations. The instruments provide AC or DC outputs and, when required, reproduce AC signals with a DC component or DC outputs with superimposed ripple.
Reproducing Grid Disturbances and Inrush Behavior
For grid simulation and DUT supply, the IT7800 Series provides output frequencies from 16 to 2400 Hz. Using LIST, SWEEP, and Surge & Sag, users change voltage, frequency, phase, and waveform as a fixed sequence or as a ramp. This makes it possible to evaluate inrush current, grid recovery, short interruptions, voltage dips, and slow ramps at the DUT input.
Harmonics, Waveforms, and Test Data Directly in the Test
The integrated AC power meter shows how voltage, current, and power behave during ramps, interruptions, and changing grid conditions. The series reproduces distorted grid waveforms using harmonic analysis up to the 50th order, built-in waveforms, CSV import, and freely editable curves.
The touchscreen displays up to six voltage and current waveforms, allowing users to assess the course of the test conditions directly on the instrument.
Selecting Power, Phase Mode, and ATE Integration
The model range extends from 2 kVA to 165 kVA and can be expanded to systems up to 960 kVA via master/slave parallel operation. The right configuration depends on output voltage, output current, power, frequency range, and phase mode. For automated test benches, the instruments provide USB, CAN, LAN, digital I/O, and optional GPIB, analog, and RS232 interfaces.
Clear Differentiation From Loads, Hipot Testers, and Regenerative Grid Simulators
The ITECH IT7800 Series supplies DUTs with defined AC/DC conditions. Load tests, hipot tests, or actively regenerative applications require other instrument classes, such as electronic loads, safety testers, or regenerative grid simulators.
Alternative Products
If higher AC voltages are required for three-phase grid simulation, the ITECH IT7800H Series is the suitable high-voltage AC source. For regenerative grid tests, four-quadrant operation, or grid-connected DUTs, consider the ITECH IT7900 Grid Simulator. If the test setup requires a defined AC/DC load instead of a source, the ITECH IT8600 Series is the appropriate instrument class.
Related Product Categories
Power Supplies / Sources | Simulators | Bidirectional Power Supplies | Electronic Loads
Plan the Right AC/DC Test Setup
Testing grid disturbances, inrush current, or AC/DC supply? We help define voltage, power, phase mode, regeneration, and interfaces for the right IT7800 configuration.
Variants
Specifications
| Output Power | 2 kVA to 165 kVA |
|---|---|
| Parallel Operation | Master/Slave parallel operation with current sharing up to 960 kVA |
| Output Voltage | 350 V L-N / 606 V L-L according to model overview; up to 700 V in Reverse Phase mode |
| Output Current | up to 990 A single-phase, up to 330 A three-phase |
| Output Frequency | 16 Hz to 2400 Hz, adjustable slew rate for voltage and frequency changes |
| Output Modes | AC, DC, AC+DC, and DC+AC |
| Phase Modes | single-phase, three-phase, and Reverse Phase / Split Phase |
| Harmonic Functions | voltage and current harmonic analysis as well as voltage harmonic simulation up to the 50th order |
| Test Modes | LIST, SWEEP, and Surge & Sag |
| IEC Functions | integrated IEC61000-3-2/3-12 functions and waveforms according to IEC61000-4-11/4-13/4-14/4-17/4-28/4-29 |
| Waveform Data | CSV import and custom waveform editing |
| Waveforms | triangle, sine, square, sawtooth, pulse, trapezoid, and DST01 |
| Harmonic Waveforms | 30 integrated harmonic distortion waveforms |
| Multi-Channel Function | up to 3 independent DUTs on one instrument, not available for 3 kVA and 5 kVA models |
| Measurement Function | integrated single-phase and three-phase AC power meter |
| Data Logging | trend display with up to 6 curves |
| Trigger Functions | trigger configuration for synchronous acquisition of the voltage waveform at the DUT |
| Phase Control | output start/stop phase angle adjustable from 0 to 360° |
| Output Impedance | programmable |
| Current Source Mode | available for single-phase operation, Reverse Phase / Split Phase, AC, and AC+DC |
| Interfaces | USB, CAN, LAN, and digital I/O integrated; GPIB, analog, and RS232 optional |
| Communication | CANopen subject to availability, Modbus, LXI, and SCPI |
| Protection Functions | OVP, OCP, OPP, OTP, FAN, ECP, and Sense |
| Power Density | up to 6 kVA in 1U / 2U, up to 15 kVA in 3U |
| Unit Height | 1U, 2U, 3U, and cabinet versions up to 37U |
| AC Input | standard models with three-phase AC input; IT7803J-350-30U as a special model with single-phase AC input |
| ATE Versions | front panel without touchscreen |
| Relay CTRL Function | relay control output for disconnecting the instrument from the DUT |
| Inter-Harmonic Waveform Synthesis | subject to availability according to the manufacturer |
Options & Accessories
| RS232/analog interface | |
| GPIB interface |
Scope of Delivery
| Instrument(s) of the IT7800 Series |
| Rack-Mount Kit (IT-E155A - only for 1U ATE models) |
| Power Cord |
| Factory Test Report |
| Operating Manual |
Applications
| Research |
| Development |
| Production test |
| Quality assurance |